| General | |
| DVM_PFC_Continuous_Conduction_Mode.sxsch |
| dvm_advanced.testplan |
| dvm_builtin-acdc_1in_1out.testplan |
| 2015-12-10 6:17 PM |
| ac_dc_built_in |
| dvm_advanced.log |
| 17 of 17 (17 of 17 Run, 10 Passed, 7 Failed, 0 Ran with Warnings, 0 Skipped) |
| 19m 32s |
|
| Design Specifications | |
| DVM_PFC_Continuous_Conduction_Mode |
| 200W Continuous Conduction Mode PFC |
| 115 VRMS Nominal (85 VRMS to 132 VRMS) |
| 230 VRMS Nominal (170 VRMS to 265 VRMS) |
| 400 V (±5%) @ 500m A |
| 50Hz |
| 60Hz |
| 100kHz |
|
| Excel-compatible Results | |
| dvm_advanced_table_scalars.txt |
| dvm_advanced_table_specs.txt |
| dvm_advanced_table_statistics.txt |
| dvm_advanced_table_statspecs.txt |
|
| Test 1 of 17 | |
| Transient|FindACSteadyState|LL_Nominal|F_High|Enabled|Light Load |
| simplis |
| Transient\FindACSteadyState\LL_Nominal\F_High\Enabled\LightLoad\report.txt.html |
| PASS |
| 1m 56s |
|
| Test 2 of 17 | |
| Transient|FindACSteadyState|HL_Maximum|F_Low|Enabled|100% Load |
| simplis |
| Transient\FindACSteadyState\HL_Maximum\F_Low\Enabled\100%Load\report.txt.html |
| PASS |
| 1m 32s |
|
| Test 3 of 17 | |
| Transient|FindACSteadyState|HL_Maximum|F_Low|Disabled|Light Load |
| simplis |
| Transient\FindACSteadyState\HL_Maximum\F_Low\Disabled\LightLoad\report.txt.html |
| PASS |
| 12s |
|
| Test 4 of 17 | |
| Transient|ACSteadyState|HL_Maximum|F_Low|Light Load |
| simplis |
| Transient\ACSteadyState\HL_Maximum\F_Low\LightLoad\report.txt.html |
| FAIL |
| 30s |
|
| Test 5 of 17 | |
| Transient|ACSteadyState|LL_Nominal|F_High|50% Load |
| simplis |
| Transient\ACSteadyState\LL_Nominal\F_High\50%Load\report.txt.html |
| FAIL |
| 30s |
|
| Test 6 of 17 | |
| Transient|ControlStartup|HL_Maximum|F_Low|Light Load |
| simplis |
| Transient\ControlStartup\HL_Maximum\F_Low\LightLoad\report.txt.html |
| PASS |
| 1m 32s |
|
| Test 7 of 17 | |
| Transient|ControlStartup|LL_Maximum|F_High|100% Load |
| simplis |
| Transient\ControlStartup\LL_Maximum\F_High\100%Load\report.txt.html |
| PASS |
| 1m 44s |
|
| Test 8 of 17 | |
| Transient|LineStartup|LL_Maximum|F_High|Light Load |
| simplis |
| Transient\LineStartup\LL_Maximum\F_High\LightLoad\report.txt.html |
| FAIL |
| 1m 39s |
|
| Test 9 of 17 | |
| Transient|LineStartup|HL_Maximum|F_Low|100% Load |
| simplis |
| Transient\LineStartup\HL_Maximum\F_Low\100%Load\report.txt.html |
| FAIL |
| 1m 11s |
|
| Test 10 of 17 | |
| Transient|LineDropout|HL_Nominal|F_Low|1Cycles|100% Load |
| simplis |
| Transient\LineDropout\HL_Nominal\F_Low\1Cycles\100%Load\report.txt.html |
| FAIL |
| 47s |
|
| Test 11 of 17 | |
| Transient|LineDropout|HL_Nominal|F_High|1Cycles|100% Load |
| simplis |
| Transient\LineDropout\HL_Nominal\F_High\1Cycles\100%Load\report.txt.html |
| FAIL |
| 41s |
|
| Test 12 of 17 | |
| Transient|LineSag|HL_Nominal_to_HL_Sag|F_Low|50% Load |
| simplis |
| Transient\LineSag\HL_Nominal_to_HL_Sag\F_Low\50%Load\report.txt.html |
| PASS |
| 1m 24s |
|
| Test 13 of 17 | |
| Transient|LineSag|LL_Nominal_to_LL_Sag|F_High|100% Load |
| simplis |
| Transient\LineSag\LL_Nominal_to_LL_Sag\F_High\100%Load\report.txt.html |
| FAIL |
| 1m 17s |
|
| Test 14 of 17 | |
| Transient|LineSurge|HL_Maximum_to_HL_Surge|F_High|Light Load |
| simplis |
| Transient\LineSurge\HL_Maximum_to_HL_Surge\F_High\LightLoad\report.txt.html |
| PASS |
| 40s |
|
| Test 15 of 17 | |
| Transient|LineSurge|HL_Maximum_to_HL_Surge|F_Low|100% Load |
| simplis |
| Transient\LineSurge\HL_Maximum_to_HL_Surge\F_Low\100%Load\report.txt.html |
| PASS |
| 1m 14s |
|
| Test 16 of 17 | |
| Transient|LoadTrAC|LL_Nominal|F_High|Light Load to 50% Load to Light Load |
| simplis |
| Transient\LoadTrAC\LL_Nominal\F_High\LightLoad to 50% Load to Light Load\report.txt.html |
| PASS |
| 1m 11s |
|
| Test 17 of 17 | |
| Transient|LoadTrAC|HL_Nominal|F_Low|Light Load to 100% Load to Light Load |
| simplis |
| Transient\LoadTrAC\HL_Nominal\F_Low\LightLoad to 100% Load to Light Load\report.txt.html |
| PASS |
| 1m 18s |